Direkt zum Inhalt der Seite Direkt zur Hauptnavigation
 
 

DIN EN 13126-3 (Classification Key)

DIN EN 13126-3 for window handles

1st digit: Category of use
(corresponding to the main test parameter)

Grade 1

Click torque before and after durability testing Between-clicks torque
M0 ≤ 1,4 Nm
Click-out torque
Ma ≤ 6,0 Nm
Difference
Md ≥ 0,4 Nm
Free play perpendicular or parallel to the mounting plane  Δ ≤ 6 mm
Torsional strength
200 N / 85 mm / 30 s
Permissible deformation Δ ≤ 5 mm
Tensile strength of spindle connection F ≥ 100 N
Eccentric tensile strength F = 600 N

 

Grade 2

Click torque before and after durability testing Between-clicks torque
M0 ≤ 0,8 Nm
Click-out torque
Ma ≤ 4,0 Nm
Difference
Md ≥ 0,8 Nm
Free play perpendicular or parallel to the mounting plane  Δ ≤ 4 mm
Torsional strength
200 N / 85 mm / 30 s
Permissible deformation Δ ≤ 2 mm
Tensile strength of spindle connection F ≥ 100 N
Eccentric tensile strength F = 1 200 N

 

2nd digit: Durability

Grade 3/90
10.000 turn-only cycles
Grade 4/90 15.000 turn-only cycles
Grade 5/90 25.000 turn-only cycles
Grade 3/180 10.000 tilt and turn cycles
Grade 4/180 15.000 tilt and turn cycles
Grade 5/180 25.000 tilt and turn cycles

 

3rd digit: Mass

No requirement accoring to the main section of EN 13126-1

 

4th digit: Fire resistance

No requirement accoring to the main section of EN 13126-1

 

5th digit: Safety in use

Grade 1 in accordance with main section of EN 13126-1

 

6th digit: Corrosion resistance

Minimum grade 2 of EN 1670, in accordance with main section of EN 13126-1

 

7th digit: Security
(in accordance with additional test parameters)

Grade 0
Without security
Grade 1 35 Nm Nm resistance against twisting-off and forcing-off
Grade 2 100 Nm Nm resistance against twisting-off and forcing-off
Grade 3 200 Nm Nm resistance against twisting-off and forcing-off
Extension 0 No locking mechanism
Extension 1 Non-keyed locking mechanism
Extension 2 Keyed locking mechanism with ≤ 99 locking varieties
Extension 3 Keyed locking mechanism with ≥ 100 locking varieties

This results in the following possible combinations for the 7th digit:

0/0
Without security / without locking mechanism
1/1 35 Nm Nm resistance against twisting-off and forcing-off / nonkeyed
locking mechanism
1/2 35 Nm Nm resistance against twisting-off and forcing-off / keyed
locking mechanism with ≤ 99 locking variations
1/3 35 Nm resistance against twisting-off and forcing-off / keyed
locking mechanism with minimum 100 locking variations
2/1 100 Nm Nm resistance against twisting-off and forcing-off / nonkeyed
locking mechanism
2/2 100 Nm resistance against twisting-off and forcing-off / keyed
locking mechanism with ≤ 99 locking variations
2/3 100 Nm Nm resistance against twisting-off and forcing-off / keyed
locking mechanism with minimum 100 locking variations
3/1 200 Nm Nm resistance against twisting-off and forcing-off / nonkeyed
locking mechanism
3/2 200 Nm 200 Nm resistance against twisting-off and forcing-off / keyed
locking mechanism with ≤ 99 locking variations
3/3 200 Nm resistance against twisting-off and forcing-off / keyed
locking mechanism with minimum 100 locking variations

 

8th digit: Application

Applicable part of this European standard: Grade 3

Application N
No click function
Application C Click function
Type 1 Window handle
Type 2 Geared window handle

This results in the following possible combinations for the 8th digit:

3/N1
Part 3 / no click function / window handle
3/N2 Part 3 / no click function / geared window handle
3/C1 Part 3 / with click function / window handle
3C/2 Part 3 / with click function / geared window handle

 

9th digit: Test size

No requirement

Example:

Category of use
2
Durability 3/180
Mass
Fire resistance 0
Safety in use 1
Corrosion resistance 2
Security 3/3
Application 3/C1
Test size

 

Explanation:

1st digit: Handle with category of use grade 2
2nd digit: Tested with 10,000 tilt and turn cycles
3rd digit: No requirements for window mass (not requested)
4th digit: No requirements for fire resistance (not requested)
5th digit: Safety in use grade 1 (only provided as such)
6th digit: Corrosion resistance grade 2 according to DIN EN 1670
(corresponding to 48 h in neutral salt spray test)
7th digit: 200 Nm resistance against twisting-off and forcing off and a keyed locking mechanism with at least 100 locking variations
8th digit: Application as window handle with click mechanism
9th digit: No requirements for window test size (not requested)
Category of use grade 2 to DIN EN 13126-3