{"id":61208,"date":"2023-08-31T10:20:48","date_gmt":"2023-08-31T08:20:20","guid":{"rendered":"http:\/\/www.hoppe.com\/gb-en\/?page_id=61208"},"modified":"2025-04-04T14:12:46","modified_gmt":"2025-04-04T12:12:46","slug":"bs-8300","status":"publish","type":"page","link":"https:\/\/www.hoppe.com\/gb-en\/contacts-service\/standards\/bs-8300\/","title":{"rendered":"BS 8300-2:2018 \u2013 Design of an Accessible and Inclusive Built Environment"},"content":{"rendered":"<section class=\"wp-bootstrap-blocks-container has--bg-white\">\n\t<div class=\"container\">\n\t\t\n<div class=\"wp-bootstrap-blocks-row row\">\n\t\n\n<div class=\"col-12 col-md-3\">\n\t\t\t\t<\/div>\n\n\n\n<div class=\"col-12 col-md-6\">\n\t\t\t\n\n<h2 class=\"wp-block-heading\">Buildings \u2013 Code of Practice<\/h2>\n\n\t<\/div>\n\n\n\n<div class=\"col-12 col-md-3\">\n\t\t\t\t<\/div>\n\n<\/div>\n\n\n<div class=\"wp-bootstrap-blocks-row row\">\n\t\n\n<div class=\"col-12 col-md-3 text-md-end\">\n\t\t\t\t<\/div>\n\n\n\n<div class=\"col-12 col-md-6\">\n\t\t\t\n\n<p class=\"wp-block-paragraph\">An accessible environment is one which a disabled person can enter and make use of independently or with help from a partner or assistant, including being able to escape in the event of fire or other emergency.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This British standard applies to the following types of buildings:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Transport and industrial buildings<\/li>\n\n\n\n<li>Administrative and commercial buildings<\/li>\n\n\n\n<li>Health and welfare buildings<\/li>\n\n\n\n<li>Refreshment<\/li>\n\n\n\n<li>Religious buildings<\/li>\n\n\n\n<li>Educational, cultural and scientific buildings<\/li>\n\n\n\n<li>Residential buildings<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Door opening furniture that is easily reached, and which provides a secure grip, is of critical importance to disabled people.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To satisfy the recommendations of BS&nbsp;8300:2018, it should be possible to operate all doors opening furniture one-handed, without the need to grasp or twist. Wherever possible, door opening furniture used in conjunction with lock and latches should have lever action.<\/p>\n\n\t<\/div>\n\n\n\n<div class=\"col-12 col-md-3\">\n\t\t\t\t<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<section class=\"wp-bootstrap-blocks-container\">\n\t<div class=\"container\">\n\t\t\n<div class=\"wp-bootstrap-blocks-row row\">\n\t\n\n<div class=\"col-12 col-md-3 text-md-end\">\n\t\t\t\n\n<h3 class=\"wp-block-heading\">Lever handles:<\/h3>\n\n\t<\/div>\n\n\n\n<div class=\"col-12 col-md-6\">\n\t\t\t\n\n<p class=\"wp-block-paragraph\">Lever handles should be \u201cof the return to door type.\u201d They do not have to be round bar. They should not have sharp edges or immediate changes of direction. They should be securely fixed to door by bolt-through fixings and with minimum dimensions 95&nbsp;mm inside, 45&nbsp;mm distance away from door and min 19&nbsp;mm diameter.<\/p>\n\n\t<\/div>\n\n\n\n<div class=\"col-12 col-md-3\">\n\t\t\t\t<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<section class=\"wp-bootstrap-blocks-container has--bg-white\">\n\t<div class=\"container\">\n\t\t\n<div class=\"wp-bootstrap-blocks-row row\">\n\t\n\n<div class=\"col-12 col-md-3 text-md-end\">\n\t\t\t\n\n<h3 class=\"wp-block-heading\">Pull handles:<\/h3>\n\n\t<\/div>\n\n\n\n<div class=\"col-12 col-md-6\">\n\t\t\t\n\n<p class=\"wp-block-paragraph\">Pull handles should be bolt fixed to door and have roses to aid the partially sighted. Minimum dimensions are 45&nbsp;mm distance away from door, 19&nbsp;mm to 35&nbsp;mm diameter, and 400&nbsp;mm length. The upper fixing should be a minimum of 1400 mm above floor level. Pull handles can be longer than 400&nbsp;mm but not shorter than this.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The latest updates to BS&nbsp;8300:2018 and Approved Document \u201cM\u201d of the British Building Regulations in relation to ironmongery contain the following recommendations with regard to door operating forces, quoting a maximum figure of 30&nbsp;N opening force when measured at 0\u02da (closed) to 30\u02da and 22.5&nbsp;N when measured between 30\u02da and 60\u02da open. It is preferable that back check should not operate before about 80\u02da open and that the maximum closing force should occur between 0\u02da and 15\u02da of final closing. It is recommended that doors should also be fitted with high performance hinges which contribute less than 1&nbsp;N friction per hinge.<\/p>\n\n\t<\/div>\n\n\n\n<div class=\"col-12 col-md-3\">\n\t\t\t\t<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<section class=\"wp-bootstrap-blocks-container\">\n\t<div class=\"container\">\n\t\t\n<div class=\"wp-bootstrap-blocks-row row\">\n\t\n\n<div class=\"col-12 col-md-3 text-md-end\">\n\t\t\t\n\n<h3 class=\"wp-block-heading\">Note:<\/h3>\n\n\t<\/div>\n\n\n\n<div class=\"col-12 col-md-6\">\n\t\t\t\n\n<p class=\"wp-block-paragraph\">It should also be noted that when official testing is carried out it is done so under laboratory conditions. Therefore, it is not possible to say that the same door set and associated hardware which conforms in one location will perform identically in another as other local conditions may apply (smoke and intumescent seals along with differential air pressures being the main factors and consideration).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We have a range of products that satisfy the recommendations contained within BS&nbsp;8300:2018. However, additional consideration must be given to other installed hardware on doorsets when attempting to satisfy dimensional or opening force recommendations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Please note: Satisfying recommendations contained within BS&nbsp;8300:2018 is not mandatory.<\/strong><\/p>\n\n\t<\/div>\n\n\n\n<div class=\"col-12 col-md-3\">\n\t\t\t\t<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n\n\n<section class=\"wp-bootstrap-blocks-container has--bg-white\">\n\t<div class=\"container\">\n\t\t\n<div class=\"wp-bootstrap-blocks-row row\">\n\t\n\n<div class=\"col-12 col-md-3\">\n\t\t\t\t<\/div>\n\n\n\n<div class=\"col-12 col-md-6\">\n\t\t\t\n\n<p class=\"wp-block-paragraph\"><strong>Source:<\/strong> BSI&nbsp;Standard Publication: BS8300-2:2018&nbsp;+ A1:2010&nbsp;\u2013 Design of building to meet the needs of disabled people&nbsp;\u2013 Code of Practise<\/p>\n\n\t<\/div>\n\n\n\n<div class=\"col-12 col-md-3\">\n\t\t\t\t<\/div>\n\n<\/div>\n\n\t<\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":9,"featured_media":49281,"parent":500,"menu_order":14,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"advgb_blocks_editor_width":"","advgb_blocks_columns_visual_guide":"","footnotes":""},"class_list":["post-61208","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"coauthors":[],"author_meta":{"author_link":"https:\/\/www.hoppe.com\/gb-en\/author\/simone-stecher-hoppe\/","display_name":"simone-stecher-hoppe"},"relative_dates":{"created":"Posted 3 years ago","modified":"Updated 1 year ago"},"absolute_dates":{"created":"Posted on 31. August 2023","modified":"Updated on 4. April 2025"},"absolute_dates_time":{"created":"Posted on 31. August 2023 10:20","modified":"Updated on 4. April 2025 14:12"},"featured_img_caption":"","featured_img":"https:\/\/www.hoppe.com\/gb-en\/wp-content\/uploads\/2023\/09\/ARRONE-Headerbild-Standards-BS-8300-Design-Buildings-Meet-Needs-Disabled-People-1920-x-1080-1.jpg","series_order":"","_links":{"self":[{"href":"https:\/\/www.hoppe.com\/gb-en\/wp-json\/wp\/v2\/pages\/61208","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hoppe.com\/gb-en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.hoppe.com\/gb-en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.hoppe.com\/gb-en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hoppe.com\/gb-en\/wp-json\/wp\/v2\/comments?post=61208"}],"version-history":[{"count":10,"href":"https:\/\/www.hoppe.com\/gb-en\/wp-json\/wp\/v2\/pages\/61208\/revisions"}],"predecessor-version":[{"id":963091,"href":"https:\/\/www.hoppe.com\/gb-en\/wp-json\/wp\/v2\/pages\/61208\/revisions\/963091"}],"up":[{"embeddable":true,"href":"https:\/\/www.hoppe.com\/gb-en\/wp-json\/wp\/v2\/pages\/500"}],"wp:attachment":[{"href":"https:\/\/www.hoppe.com\/gb-en\/wp-json\/wp\/v2\/media?parent=61208"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}